ABSTRACT


In this paper, we propose a novel characterization technique of the surface acoustic wave (SAW) chemical sensors. It combines the technique of electronic frequency shifting measurement (phase lock lop) with the IR microscopic spectral analyzer and performs an in-situ measurement. Using this method, we could conduct ultrahigh sensitive measurement in mass change (from a few ppb to a few ppm range) of the SAW chemical sensors by cross-comparison with the electronic signals of the SAW device and the Fourier-Transform Infrared (FT-IR) spectro-microscopic data of the molecular imprinted polymer (MIP) recognition thin film which is deposited on the surface of the SAW device. With the use of the MIP thin films, the target recognition is functioned by identifying the geometry shape of the targets. We are able to provide a more accurate molecular selectivity and sensitivity than those current SAW chemical sensors which were based on regular chemical absorbed films. Spectrum results of MIP films will be presented herein


Keywords: Surface Acoustic Wave (SAW), Molecular Imprinted Polymer (MIP), Fourier-transform Infrared (FT-IR)


REFERENCES


  1. [1] Darrel, Ash Sr. “New Receiver Architecture Based on SAWs,” IEEE Microwave Systems Conference, pp. 205214 (1995).
  2. [2] Reindl, L., Ruppel, C. C. W., Berek, S., Knauer, U., Vossiek, M., Heide, P. and Oreans, L. “Design, Fabrication, and Application of Precise SAW Delay Lines Used in an FMCW Radar System,” Microwave Theory and Techniques, Vol. 49, pp. 787794 (2001).
  3. [3] Stubbs, D. D., Lee, Sang-Hun and Hunt, W. D. “Molecular Recognition for Electronic Noses Using Surface Acoustic Wave Immunoassay Sensors,” IEEE Sensors Journal, Vol. 2, pp. 294300 (2002).
  4. [4] Nomura, T., Takebayashi, R. and Saitoh, A. “Chemical Sensor Based on Surface Acoustic Wave Resonator Using Langmuir-Blodgett Film,” Ultrasonics, Ferroelectrics and Frequency Control, Vol. 45, pp. 1261 1265 (1998).
  5. [5] Wu, L., Shen, J. Y. and Shen, Y. T., “Surface Acoustic Wave Based Chemical Sensors,” Chemistry, Vol. 59, pp. 279286 (2001).
  6. [6] Lee, Yian-Cheng, “The Development and Applications of Fourier Transformed Infrared Spectroscopic Chemical Imaging Technology,” Measurement Technology, Vol. 89, pp. 2429 (2003).
  7. [7] Lo, Yi-Chung, Chen, Ching-Iue andCheng, Chien-Hung, “The Development and Applications of Synchrotron Radiation Based FT-IR Spectro-Microscopic Technology-Part I,” Frontier of Scientific Instrumentations, Vol. 23, pp. 6371 (2001).