Journal of Applied Science and Engineering

Published by Tamkang University Press

1.30

Impact Factor

1.60

CiteScore

Shi-Hung Hoang1 , Gor-Don Horng1 , Chen-Yu Chiang1 , Cheng-Hao Ko This email address is being protected from spambots. You need JavaScript enabled to view it.1, Yi-Chung Lo2 , Ching-Iue Chen2 and Chao-Kang Chang3

1Graduate School of Electro-Optical Engineering Yuan Ze University Chungli, Taiwan 320, R.O.C.
2National Synchrotron Radiation Research Center Hsinchu, Taiwan 300, R.O.C.
3Union Chemical Laboratories Industrial Technology Research Institute Hsinch, Taiwan 300, R.O.C.


 

Received: February 11, 2004
Accepted: February 25, 2004
Publication Date: June 1, 2004

Download Citation: ||https://doi.org/10.6180/jase.2004.7.2.09  


ABSTRACT


In this paper, we propose a novel characterization technique of the SAW chemical sensors. It combines the technique of electronic frequency shifting measurement (phase lock lop) with the IR microscopic spectral analyzer and performs a in-situ measurement. Using this method, we could conduct ultrahigh sensitive measurement in mass change (a few ppb-a few ppm range) of the SAW chemical sensors by cross-compared with the electronic signals of the SAW device and the FT-IR spectro-microscopic data of the molecular imprinted polymer (MIP) recognition thin film which deposit on the surface of the SAW device. With the use of the MIP thin films, we are able to provide a more accurate molecular selectivity than those current SAW chemical sensors which were based on regular chemical absorb films. Spectrum results of MIP films will be presented below.


Keywords: SAW, MIP, FT-IR


REFERENCES


  1. [1] Darrel, A. Sr., “New Receiver Architecture Based on SAWs,” IEEE Microwave Systems Conference, pp. 205-214 (1995).
  2. [2] Reindl, L., Ruppel, C. C. W., Berek, S., Knauer, U., Vossiek, M., Heide, P. and Oreans, L., “Design, Fabrication, and Application of Precise SAW Delay Lines Used in an FMCW Radar System”, Microwave Theory and Techniques, Vol. 49, pp. 787-794 (2001).
  3. [3] Stubbs, D. D., Lee, S. H. and Hunt, W. D., “Molecular Recognition for Electronic Noses Using Surface Acoustic Wave Immunoassay Sensors”, Sensors Journal, IEEE, Vol. 2, pp. 294-300 (2002).
  4. [4] Nomura, T., Takebayashi, R. and Saitoh, A., “Chemical Sensor Based On Surface Acoustic Wave Resonator Using LangmuirBlodgett Film,” Ultrasonics, Ferroelectrics and Frequency Control, Vol. 45, pp. 1261-1265, 1998 (2001).
  5. [5] Wu., L., Shen, J. Y., Shen, Y. T., “Surface Acoustic Wave Based Chemical Sensors”, Chemistry, Vol. 59, pp. 279-286 (2001).
  6. [6] Li, Y. C., “Applications and Development of Fourier-Transformed Spectromicroscopy for Chemical Imaging”, Information Technology Measuremnet, Vol. 89, pp. 24-29 (2003).
  7. [7] Lo, Y. C., Chen, C. Y., Chen, J. H., “The Applications of Fourier-Transformed Infrared Spectroscopy Using Synchrotron Radiation Source (I),” Instrument Updates, Vol. 23, pp. 63-71 (2001).