Jiun-Min Wang1 and Lung-Jieh Yang This email address is being protected from spambots. You need JavaScript enabled to view it.1

1Department of Mechanical and Electro-Mechanical Engineering, Tamkang University Tamsui, Taiwan 251, R.O.C.


 

Received: January 10, 2005
Accepted: March 21, 2005
Publication Date: September 1, 2005

Download Citation: ||https://doi.org/10.6180/jase.2005.8.3.09  


ABSTRACT


This paper describes an ejection-type electro-hydro-dynamic (EHD) micropump using various types of polymers to protect the electrodes. The polymer layers of parylene and crosslinked gelatin were shown to protect the gold electrodes from electrolytic aging. The pump chip is packaged by the polydimethylsiloxane (PDMS) bonding technique. The results show that the polymer protection layers are successful in prolonging the operation lifetime. They can also provide the inner walls of channels with different surface properties for the working liquid to be driven through.


Keywords: Parylene, Gelatin, Surface Modification, Electro-Hydro-Dynamic (EHD)


REFERENCES


  1. [1] Kovacs, G. T. A., Micromachined Transducers Sourcebook, McGraw-Hill, Chapter 9, p. 845 (2000).
  2. [2] Richter, A. and Sandmaier, H., “An EHD Pump,” Proc. IEEE MEMS’90, pp. 99104 (1990).
  3. [3] Ahn, S. H. and Kim, Y. K., “Fabrication and Experiment of a Planar Micro Ion Drag Pump,” Sensors and Actuators A, Vol. 70, pp.15 (1998).
  4. [4] Yang, L. J., Wang, J. M. and Huang, Y. L., “The Micro Ion Drag Pump Using Indium-Tin-Oxide (ITO) Electrodes to Resist Aging,” Proc. IEEE MEMS’03, pp. 112115 (2003), or Sensors and Actuators A, Vol. 111, pp. 118122 (2004).
  5. [5] Madou, M., Fundamentals of Microfabrication, CRC Press, Chapter 9, p. 433 (1997).
  6. [6] Crowley, J. M., Wrigh, G. S. and Chato, J. C., “Selecting a Working Fluid to Increase the Efficiency and Flow Rate of an EHD Pump,” IEEE Transactions on Industry Applications, Vol. 26, pp. 4249 (1990).
  7. [7] Anderson, J. R., Chiu, D. T., Jackman, R. J., Chemiavskaya, O., McDonald, J. C., Wu, H., Whitesides, S. H. and Whitesides, G. M., “Fabrication of Topologically Complex Three-Dimensional Microfluidic Systems in PDMS by Rigid Prototyping,” Analytical Chem., Vol. 72, pp. 31583164 (2000).
  8. [8] Xu, C., Lemon, W. and Lui, C., “Design and Fabrication of A High-Density Metal Microelectrode Array for Neural Recording,” Sensors and Actuators A, Vol. 96, pp. 7885 (2002).
  9. [9] Yang, L. J., Lin, W. Z., Yao, T. J. and Tai, Y. C., “Photo-Patternable Gelatin as Protection Layers in Surface Micromachinings,” Proc. IEEE MEMS’02, pp. 471474 (2002); or Sensors and Actuators A, Vol. 103, pp. 284290 (2003).
  10. [10] Madou, M., Fundamentals of Microfabrication, CRC Press, Chapter 9, p. 432 (1997).
  11. [11] Sze, A., Erickson, D., Ren, L. and Li, D., “ZetaPotential Measurement Using The Smoluchowski Equation and The Slop of The Current-Time Relationship in Electroosmosis Flow,” Journal of Colloid and Interface Science, Vol. 261, pp. 402410 (2003).