P. M. Hoby1, A. S. Santhi This email address is being protected from spambots. You need JavaScript enabled to view it.1, and G. Mohan Ganesh1

1Vellore Institute of Technology, Vellore - 632014, India


 

Received: November 4, 2021
Accepted: January 25, 2022
Publication Date: February 28, 2022

 Copyright The Author(s). This is an open access article distributed under the terms of the Creative Commons Attribution License (CC BY 4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are cited.


Download Citation: ||https://doi.org/10.6180/jase.202212_25(6).0018  


ABSTRACT


Exposure to the marine environment causes a gradual diminution in the strength and resistance to corrosion of a reinforced concrete structure. Studies about the behavior of blended concrete exposed to marine environments in arid regions are less in numbers and in-depth analyses are not widely available. This research aimed to study the structural behavior and corrosion resistance of blended cement concrete exposed to seawater in an arid region (Muscat, Oman) for one year. Four mixes namely, control mix (100% cement), two binary blended mixes (90% cement+10% silica fume and 60% cement+40% fly ash) and one ternary mix (50% cement+40% fly ash+10% silica fume) were used for tests. Each sample for the experiment was prepared to attribute 25 mm and 50 mm covers to the reinforcement. The samples were cured in normal water and seawater under the worst condition of alternate wet and dry, in the natural weather of the Muscat region for up to one year. The mechanical properties were assessed and the corrosion behavior was analyzed by an accelerated corrosion test. Scanning Electron Microscopy (SEM) was done on the samples for microstructure analysis. The test results indicate that the ternary blended concrete mix gives the maximum compressive split tensile strength and minimum corrosion. The results of SEM analysis were in concordant with the experimental results. Using regression analysis, an empirical equation was formulated to predict the weight loss of rebar in an accelerated corrosion test. The equation has been validated using the experimental data from other authors.


Keywords: Blended concrete, fly ash, silica fume, binary, ternary, scanning electron microscopy, accelerated corrosion test


REFERENCES


  1. [1] S. Murugan, G. Ganesh, and A. Santhi, (2012) “Regression models for prediction of compressive strength of high volume fly ash (HVFA) concrete" Arabian Journal for Science and Engineering 39(3): 1659–1669. DOI: 10.1007/s13369-013-0783-y.
  2. [2] T. Hemalatha and A. Ramaswamy, (2017) “A review on fly ash characteristics – Towards promoting high volume utilization in developing sustainable concrete" Journal of Cleaner Production 147: 546–559. DOI: 10.1016/j.jclepro.2017.01.114.
  3. [3] V. Horsakulthai and K. Paopongpaiboon, (2013) “Strength, chloride permeability and corrosion of coarse fly ash concrete with Bagasse-Rice Husk-Wood Ash additive" American Journal of Applied Sciences 10(3): 239–246. DOI: 10.3844/ajassp.2013.239.246.
  4. [4] P. Nithya and G. Mathew, (2016) “Effect of fly ash on corrosion potential of steel in concrete" Int. Res. J. Eng. Technol. 3(9): 860–864.
  5. [5] A. Elahi, P. Basheer, S. Nanukuttan, and Q. Khan, (2010) “Mechanical and durability properties of high performance concretes containing supplementary cementitious materials" Construction and Building Materials 24(3): 292–299. DOI: 10.1016/j.conbuildmat.2009.08.045.
  6. [6] T. Nochaiya, W. Wongkeo, and A. Chaipanich, (2010) “Utilization of fly ash with silica fume and properties of Portland cement-fly ash-silica fume concrete" Fuel 89(3): 768–774. DOI: 10.1016/j.fuel.2009.10.003.
  7. [7] Hariharan, A. R., Santhi, A. S., and G. Mohan Ganesh, (2011) “Study on Strength Development of High Strength Concrete Containing Fly ash and Silica fume" International Journal of Engineering Science and Technology 3(4): 2955–2961.
  8. [8] P. Hoby, A. Santhi, and G. Ganesh, (2017) “The performance of multi blended cement concrete in marine environment" International Journal of Civil Engineering and Technology 8(7): 219–231.
  9. [9] R. Bajpai, K. Choudhary, A. Srivastava, K. Sangwan, and M. Singh, (2020) “Environmental impact assessment of fly ash and silica fume based geopolymer concrete" Journal of Cleaner Production 254: DOI: 10.1016/j.jclepro.2020.120147.
  10. [10] Indian Standard Specification for Silica Fume. Standard. Bureau of Indian Standards, New Delhi, 2003.
  11. [11] Indian Standard Pulverized fuel ash-Specification Part-1. Standard. Bureau of Indian Standards, New Delhi, 2013.
  12. [12] Concrete Mix Proportioning - Guidelines. Standard. Bureau of Indian Standards, New Delhi, (First Revision), 2009.
  13. [13] Concrete Admixtures - Specification. Standard. Bureau of Indian Standards, New Delhi, 1999.
  14. [14] Methods of Tests for Strength of Concrete. Standard. Bureau of Indian Standards, New Delhi, Reaffirmed, 1959.
  15. [15] Standard Test Method for Half-Cell Potentials of Uncoated Reinforcing Steel in Concrete. Standard. Astm, 2015.
  16. [16] G. Malumbela, P. Moyo, and M. Alexander, (2012) “A step towards standardising accelerated corrosion tests on laboratory reinforced concrete specimens" Journal of the South African Institution of Civil Engineering 54(2): 78–85.
  17. [17] A. Hassan, K. Hossain, and M. Lachemi, (2009) “Corrosion resistance of self-consolidating concrete in full-scale reinforced beams" Cement and Concrete Composites 31(1): 29–38. DOI: 10.1016/j.cemconcomp.2008.10.005.
  18. [18] G. Koga, B. Albert, and R. Nogueira, (2018) “Revisiting the ASTM C876 standard for corrosion of reinforcing steel: On the correlation between corrosion potential and polarization resistance during the curing of different cement mortars" Electrochemistry Communications 94: 1–4. DOI: 10.1016/j.elecom.2018.07.017.
  19. [19] Y. Song, E. Wightman, Y. Tian, K. Jack, X. Li, H. Zhong, P. Bond, Z. Yuan, and G. Jiang, (2019) “Corrosion of reinforcing steel in concrete sewers" Science of the Total Environment 649: 739–748. DOI: 10.1016/j.scitotenv.2018.08.362.
  20. [20] M. Radlinski and J. Olek, (2012) “Investigation into the synergistic effects in ternary cementitious systems containing portland cement, fly ash and silica fume" Cement and Concrete Composites 34(4): 451–459. DOI: 10.1016/j.cemconcomp.2011.11.014.
  21. [21] A. Diab, H. Elyamany, and A. Abd Elmoty, (2011) “Effect of mix proportions, seawater curing medium and applied voltages on corrosion resistance of concrete incorporating mineral admixtures" Alexandria Engineering Journal 50(1): 65–78. DOI: 10.1016/j.aej.2011.01.013.
  22. [22] P. Monteiro. Concrete: microstructure, properties, and materials. McGraw-Hill Publishing, 2006.