{"id":5373,"date":"2026-05-03T12:34:18","date_gmt":"2026-05-03T04:34:18","guid":{"rendered":"\/jase\/?post_type=tkuisotope&#038;p=5373"},"modified":"2026-06-26T18:06:37","modified_gmt":"2026-06-26T10:06:37","slug":"a-new-high-gain-ac-decoupled-transformerless-inverter-for-photovoltaic-applications","status":"publish","type":"tkuisotope","link":"\/jase\/?tkuisotope=a-new-high-gain-ac-decoupled-transformerless-inverter-for-photovoltaic-applications","title":{"rendered":"A New High Gain AC-Decoupled Transformerless Inverter for Photovoltaic Applications"},"content":{"rendered":"\n<div class=\"wp-block-tkuwpbs5-bs5-row row article-info\">\n<div class=\"wp-block-tkuwpbs5-bs5-column col-md-3 align-self-start\">\n<p><i class=\"fa fa-folder\" aria-hidden=\"true\"><\/i>&nbsp;<a href=\"\/jase\/?page_id=4854\" data-type=\"page\" data-id=\"807\">2022<\/a><\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-tkuwpbs5-bs5-column col-md-3 align-self-start\">\n<p><i class=\"fa fa-folder-open\" aria-hidden=\"true\"><\/i>&nbsp;<a href=\"\/jase\/?page_id=5365\" data-type=\"page\" data-id=\"4630\">Volume 25, Issue 6<\/a><\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-tkuwpbs5-bs5-column col-md-6 align-self-start\">\n<div class=\"wp-block-tkuwpbs5-bs5-div dv_publish\" data-aos=\"normal\"><div class=\"wp-block-post-date\"><time datetime=\"2026-05-03T12:34:18+08:00\">2026-05-03<\/time><\/div><\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-tkuwpbs5-bs5-row row\">\n<div class=\"wp-block-tkuwpbs5-bs5-column col-md-5 align-self-start\">\n<div class=\"wp-block-tkuwpbs5-bs5-div au-ol\" data-aos=\"normal\">\n<p>Sahaya A Ponrekha<sup>1,2<\/sup>, M.S.P. Subathra<sup>1<\/sup>, and C. Bharatiraja<sup>2<\/sup><a href=\"mailto:bharatiraja@gmail.com\"><i class=\"fa fa-envelope\"><\/i><\/a><\/p>\n\n\n\n<p style=\"font-size:14px\"><sup>1<\/sup>Department of Electrical and Electronics Engineering, Karunya Institute of Technology and Sciences, Coimbatore, Tamilnadu, India, 641114 <\/p>\n\n\n\n<p style=\"font-size:14px\"><sup>2<\/sup>Department of Electrical and Electronics Engineering, SRM Institute of Science and Technology, Kattankulathur, Tamilnadu, India, 603203<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-tkuwpbs5-bs5-div\" style=\"margin-top:var(--wp--preset--spacing--40)\" data-aos=\"normal\">\n<p>Received:\u00a0July 27, 2021<br>Accepted:\u00a0December 16, 2021<br>Publication Date:\u00a0May 03, 2026<\/p>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-tkuwpbs5-bs5-column col-md-7 align-self-start clk=\u5716\u7247\"><img decoding=\"async\" src=\"\/jase\/wp-content\/uploads\/2026\/05\/25_6_06.jpg\" class=\"img-fluid img-fluid mx-auto d-block\" alt=\"\u4e0a\u50b3\u5716\u7247\">\n\n\n<p class=\"has-text-align-center img_caption\">(a) Structure of proposed topology (b) Switching pulses<\/p>\n<\/div>\n<\/div>\n\n\n\n<p class=\"has-small-font-size\"><i class=\"fab fa-creative-commons\"><\/i>&nbsp;<strong>Copyright&nbsp;<\/strong>The Author(s). This is an open access article distributed under the terms of the&nbsp;<a rel=\"noreferrer noopener\" href=\"https:\/\/creativecommons.org\/licenses\/by\/4.0\/\" target=\"_blank\">Creative Commons Attribution&nbsp;License (CC BY 4.0)<\/a>, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are cited.<\/p>\n\n\n\n<p>Download Citation:&nbsp; <a href=\"\/jase\/wp-content\/uploads\/2026\/05\/V256.0006.bib\" data-type=\"attachment\" data-id=\"5393\" target=\"_blank\" rel=\"noreferrer noopener\">BibTeX <\/a>| <a href=\"http:\/\/dx.doi.org\/10.6180\/jase.202212_25(6).0006\" target=\"_blank\" rel=\"noreferrer noopener\">http:\/\/dx.doi.org\/10.6180\/jase.202212_25(6).0006<\/a>&nbsp;&nbsp;<\/p>\n\n\n\n<p class=\"btn btn-primary article-btn\"><a href=\"\/jase\/wp-content\/uploads\/2026\/05\/06_2021_0536_V25i6.pdf\" data-type=\"attachment\" data-id=\"5432\" target=\"_blank\" rel=\"noreferrer noopener\">Download PDF<\/a><\/p>\n\n\n\n<div style=\"height:24px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>Transformerless inverters are prominently used in the single-phase grid-connected system due to their reduced size, weight, and high efficiency. Common-mode leakage current is the main issue of transformerless inverters, which has to be mitigated. An AC-decoupled high gain inverter is proposed in the inverter capable of attaining the gain more than ten times. Hence, even if the PV voltage is less, the inverter can continue to supply the grid. Unlike the two-stage inverters, the proposed inverter doesn\u2019t require the DC-link capacitor, and it\u2019s charging diode between the boosting and inverter stages. The AC-decoupling method used in the inverter helps to reduce the leakage current within the German standard limit VDE0126-1-1. A detailed steady-state analysis of the inverter is presented. The proposed inverter is simulated in the MATLAB Simulink platform to validate its working principle. The comparative loss and thermal analysis of the semiconductor switches made of three different materials (Gallium Nitride, Silicon Carbide, and Silicon) are made in the PLECS platform. The comparative analysis proves that the proposed inverter with Gallium Nitride made switches offers higher efficiency and reliability.<\/p>\n\n\n\n<p><em>Keywords:\u00a0Transformerless inverter, Common-mode voltage, Common-mode leakage current, Loss analysis.<\/em><\/p>\n\n\n\n<div style=\"height:2rem\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-tkuwpbs5-bs5-div ref_ol\" data-aos=\"normal\">\n<ol>\n<li>[1] T. Hou, Y. Chen, Y. Chen, and C. Bao, (2021) \u201cResearch on control of a new quasi-Z source photovoltaic grid-connected inverter based on power feedforward and optimized PCI of bacterial foraging&#8221; Journal of Applied Science and Engineering (Taiwan) 24(4): 595\u2013609. DOI: 10.6180\/jase.202108_24(4).0015.<\/li>\n<li>[2] M. Shayestegan, (2018) \u201cOverview of grid-connected two-stage transformer-less inverter design&#8221; Journal of Modern Power Systems and Clean Energy 6(4): 642655. DOI: 10.1007\/s40565-017-0367-z.<\/li>\n<li>[3] W. Li, Y. Gu, H. Luo, W. Cui, X. He, and C. Xia, (2015) \u201cTopology review and derivation methodology of single-phase transformerless photovoltaic inverters for leakage current suppression&#8221; IEEE Transactions on Industrial Electronics 62(7): 4537\u20134551. DOI: 10.1109\/TIE.2015. 2399278.<\/li>\n<li>[4] P. Madasamy, V. Kumar, P. Sanjeevikumar, J. HolmNielsen, E. Hosain, and C. Bharatiraja, (2019) \u201cA three-phase transformerless T-Type- NPC-MLI for grid connected PV systems with common-mode leakage current mitigation&#8221; Energies 12(12): DOI: 10 . 3390 \/ en12122434.<\/li>\n<li>[5] T. Shimizu, O. Hashimoto, and G. Kimura, (2003) \u201cA novel high-performance utility-interactive photovoltaic inverter system&#8221; IEEE Transactions on Power Electronics 18(2): 704\u2013711. DOI: 10.1109\/TPEL.2003.809375.<\/li>\n<li>[6] <span class=\"citation-1311 citation-1312 citation-end-1312\">A. Kadam and A. Shukla, (2017) \u201cA Multilevel Transformerless Inverter Employing Ground Connection between PV Negative Terminal and Grid Neutral Point&#8221; IEEE Transactions on Industrial Electronics 64(11): 8897\u201389<\/span><span class=\"citation-1311 citation-end-1311\">07. DOI: 10.1109\/TIE.2017.2696460.<\/span><\/li>\n<li>[7] R. Barzegarkhoo, Y. Siwakoti, N. Vosoughi, and F. Blaabjerg, (2021) \u201cSix-Switch Step-Up CommonGrounded Five-Level Inverter with Switched-Capacitor Cell for Transformerless Grid-Tied PV Applications&#8221; IEEE Transactions on Industrial Electronics 68(2): 1374\u20131387. DOI: 10.1109\/TIE.2020.2967674.<\/li>\n<li>[8] B. Chen, B. Gu, J.-S. Lai, W. Yu, C.-Y. Lin, and C. Zheng. \u201cCurrent distortion correction in dual buck photovoltaic inverter with a novel PWM modulation and control method\u201d. In: 2013, 727\u2013731. DOI: 10.1109\/ APEC.2013.6520290.<\/li>\n<li>[9] B. Yang, W. Li, Y. Gu, W. Cui, and X. He, (2012) \u201cImproved transformerless inverter with common-mode leakage current elimination for a photovoltaic grid-connected power system&#8221; IEEE Transactions on Power Electronics 27(2): 752\u2013762. DOI: 10.1109\/TPEL.2011.2160359.<\/li>\n<li>[10] H. Schmidt, C. Siedle, and J. Ketterer. DC\/AC converter to convert direct electric voltage into alternating voltage or into alternating current. US patent 7046534. 2006.<\/li>\n<li><span class=\"citation-1310 citation-end-1310\">[11] S. Kuncham, K. Annamalai, and N. Subrahmanyam, (2020) \u201cA Two-Stage T-Type Hybrid Five-Level Transformerless Inverter for PV Applications&#8221; IEEE Transactions on Power Electronics 35(9): 9512\u20139523. DOI: 10.1109\/TPEL.2020.<\/span>2973340.<\/li>\n<li>[12] H. Xiao, X. <span class=\"citation-1309 citation-end-1309\">Liu, and K. Lan, (2014) \u201cZero-voltage transition full-bridge topologies for transformerless photovoltaic grid-connected inverter&#8221; IEEE Transactions on Industrial Electronics 61(10): 5393\u20135401. DOI: 10. 1109\/TIE.2014.23<\/span>00044.<\/li>\n<li>[13] H. Xiao, K. Lan, B. Zhou, L. Zhang, and Z. Wu, (2015) \u201cA family of zero-current-transition transformerless photovoltaic grid-connected inverter&#8221; IEEE Transactions on Power Electronics 30(6): 3156\u20133165. DOI: 10.1109\/ TPEL.2014.2337513.<\/li>\n<li><span class=\"citation-1308 citation-end-1308\">[14] L. Breazeale and R. Ayyanar, (2014) \u201cA photovoltaic array transformer-less inverter with film capacitors and silicon carbide transistors&#8221; IEEE Transactions on Power Electronics 30(3): 1297\u20131305. DOI: 10.1109\/TPEL. 2014.2<\/span>321760.<\/li>\n<li><span class=\"citation-1307 citation-end-1307\">[15] A. Anurag, N. Deshmukh, A. Maguluri, and S. Anand, (2018) \u201cIntegrated DC-DC Converter Based Grid-Connected Transformerless Photovoltaic Inverter With Extended Input Voltage Range&#8221; IEEE Transactions on Power Electronics<\/span> 33(10): 8322\u20138330. DOI: 10.1109\/TPEL.2017.2779144.<\/li>\n<li>[16] S. Dhara and V. Somasekhar, (2020) \u201c<span class=\"citation-1383 citation-1384 citation-end-1384\">An Integrated Semi-Double Stage-Based Multilevel Inverter with Voltage Boosting Scheme for Photovoltaic Systems&#8221; IEEE Journal of Emerging and Selected Topics in Power Electronics 8(3): 2326\u20132339. DOI: 10.1109\/JES<\/span><span class=\"citation-1383 citation-end-1383\">TPE. 2019.2955729.<\/span><\/li>\n<li><span class=\"citation-1382 citation-end-1382\">[<\/span>17] M. Salvador, T. Lazzarin, and R. Coelho, (2018) \u201cHigh Step-Up DC-DC Converter with Active Switched Inductor and Passive Switched-Capacitor Networks&#8221; IEEE Transactions on Industrial Electronics 65(7): 5644\u20135654. DOI: 10.1109\/TIE.2017.2782239.<\/li>\n<li>[18] T. Freddy, N. Rahim, W.-P. Hew, and H. Che, (2014) \u201cComparison and analysis of single-phase transformerless grid-connected PV inverters&#8221; IEEE Transactions on Power Electronics 29(10): 5358\u20135369. DOI: 10.1109\/ TPEL.2013.2294953.<\/li>\n<li>[<span class=\"citation-1379 citation-1380 citation-1381 citation-end-1381\">19] M. Khan, Y. Siwakoti, L. Li, and F. Blaabjerg, (2020) \u201cH-Bridge zero-voltage switch-controlled rectifier transformerless midpoint-clamped inverter for photovoltaic applications&#8221; IEEE Journal of Emerging and Selected Topics in Power Electronics 8(4): 438<\/span><span class=\"citation-1379 citation-1380 citation-end-1380\">2\u20134394. DOI: 10.1109\/JE<\/span><span class=\"citation-1379 citation-end-1379\">STPE.2019.293<\/span>8224.<\/li>\n<li>[20] M. Khan, M. Forouzesh, Y. Siwakoti, L. Li, T. Kerekes, and F. Blaabjerg, (2020) \u201cTransformerless Inverter Topologies for Single-Phase Photovoltaic Systems: A Comparative Review&#8221; IEEE Journal of Emerging and Selected Topics in Power Electronics 8 (1):805\u2013835. DOI: 10.1109\/JESTPE.2019.2908672.<\/li>\n<li>[21] F. Asadi and K. Eguchi. Simulation of Power Electronics Converters Using PLECS\u00ae. Academic Press, 2019.<\/li>\n<li>[22] MS Windows NT Kernel Description. https:\/\/www. <a class=\"ng-star-inserted\" href=\"https:\/\/www.google.com\/search?q=https:\/\/plexim.com\/sites\/default\/files\/tutorials\/thermal\" target=\"_blank\" rel=\"noopener\" data-hveid=\"0\" data-ved=\"0CAAQ_4QMahgKEwjy9cmyz6SVAxUAAAAAHQAAAAAQjgE\">plexim.com\/sites\/default\/files\/tutorials\/thermal<\/a>_ domain. Accessed: 2021-09-30.<\/li>\n<li>[23] Thermal Simulation Accounting for Switching and Conduction Losses. https: \/\/<a class=\"ng-star-inserted\" href=\"https:\/\/www.plexim.com\/products\/plecs\/thermal\" target=\"_blank\" rel=\"noopener\" data-hveid=\"0\" data-ved=\"0CAAQ_4QMahgKEwjy9cmyz6SVAxUAAAAAHQAAAAAQjwE\">www.plexim.com\/products\/plecs\/thermal<\/a>. Accessed: 2021-09-30.<\/li>\n<li>[24] R. Mitova, R. Ghosh, U. Mhaskar, D. Klikic, M.-X. Wang, and A. Dentella, (2014) \u201cInvestigations of 600-v gan HEMT and GaN diode for power converter applications&#8221; IEEE Transactions on Power Electronics 29(5): 2441\u20132452. DOI: 10.1109\/TPEL.2013.2286639.<\/li>\n<li>[25] C. Bharatiraja, K. Lakshmikhandan, M. Kamalesh, D. Rajasekaran, and B. Twala, (2021) \u201cA non-isolated high-gain dc to dc converter connected multi-level inverter for photo-voltaic energy sources&#8221; Journal of Applied Science and Engineering (Taiwan) 24(3): 415\u2013422. DOI: 10.6180\/jase.202106_24(3).0017.<\/li>\n<\/ol>\n<\/div>\n\n\n\n<p><\/p>\n","protected":false},"author":3,"template":"wp-custom-template-detail-4-aricles","meta":{"_uag_custom_page_level_css":""},"categories":[936,6,942],"tags":[1058],"acf":[],"uagb_featured_image_src":[],"uagb_author_info":{"display_name":"\u6797\u923a\u6db5","author_link":"\/jase\/?author=3"},"uagb_comment_info":0,"uagb_excerpt":"&nbsp;Copyright&nbsp;The Author(s). This is an open access article distributed under the terms of the&nbsp;Creative Commons Attribution&nbsp;License (CC BY 4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are cited. Download Citation:&nbsp; BibTeX | http:\/\/dx.doi.org\/10.6180\/jase.202212_25(6).0006&nbsp;&nbsp; Download PDF Transformerless inverters are prominently used in the single-phase grid-connected system due&hellip;","_links":{"self":[{"href":"\/jase\/index.php?rest_route=\/wp\/v2\/tkuisotope\/5373"}],"collection":[{"href":"\/jase\/index.php?rest_route=\/wp\/v2\/tkuisotope"}],"about":[{"href":"\/jase\/index.php?rest_route=\/wp\/v2\/types\/tkuisotope"}],"author":[{"embeddable":true,"href":"\/jase\/index.php?rest_route=\/wp\/v2\/users\/3"}],"wp:attachment":[{"href":"\/jase\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=5373"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"\/jase\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=5373"},{"taxonomy":"post_tag","embeddable":true,"href":"\/jase\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=5373"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}