{"id":3835,"date":"2026-04-25T23:01:24","date_gmt":"2026-04-25T15:01:24","guid":{"rendered":"\/jase\/?post_type=tkuisotope&#038;p=3835"},"modified":"2026-04-26T20:06:39","modified_gmt":"2026-04-26T12:06:39","slug":"jase-202609-32-017","status":"publish","type":"tkuisotope","link":"\/jase\/?tkuisotope=jase-202609-32-017","title":{"rendered":"Linear Extended State Observer-Based Backstepping Sliding Mode Control For DC-Bus Voltage Regulation Under Constant Power Loads In DC Microgrids"},"content":{"rendered":"\n<div class=\"wp-block-tkuwpbs5-bs5-row row article-info\">\n<div class=\"wp-block-tkuwpbs5-bs5-column col-md-3 align-self-start\">\n<p><i class=\"fa fa-folder\" aria-hidden=\"true\"><\/i>&nbsp;<a href=\"\/jase\/?page_id=807\" data-type=\"page\" data-id=\"807\">2026<\/a><\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-tkuwpbs5-bs5-column col-md-3 align-self-start\">\n<p><i class=\"fa fa-folder-open\" aria-hidden=\"true\"><\/i>&nbsp;<a href=\"\/jase\/?page_id=3671\" data-type=\"page\" data-id=\"1055\">Volume 32<\/a><\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-tkuwpbs5-bs5-column col-md-6 align-self-start\">\n<div class=\"wp-block-tkuwpbs5-bs5-div dv_publish\" data-aos=\"normal\"><div class=\"wp-block-post-date\"><time datetime=\"2026-04-25T23:01:24+08:00\">2026-04-25<\/time><\/div><\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-tkuwpbs5-bs5-row row\">\n<div class=\"wp-block-tkuwpbs5-bs5-column col-md-5 align-self-start\">\n<div class=\"wp-block-tkuwpbs5-bs5-div au-ol\" data-aos=\"normal\">\n<p>Huu-Thai Pham<sup>1<\/sup>, Dinh-Nhon Truong<sup>1<\/sup>, Van-Phong Vu<sup>1<\/sup>, Minh-Tam Nguyen<sup>1<\/sup>, Ngoc-Hoai-An Nguyen<sup>2<\/sup>, and Hoai-An Trinh<sup>1<\/sup><a href=\"mailto:anth@hcmute.edu.vn\"><i class=\"fa fa-envelope\"><\/i><\/a><\/p>\n\n\n\n<p style=\"font-size:14px\"><sup>1<\/sup>Faculty of Electrical and Electronics Engineering, Ho Chi Minh City University of Technology and Engineering, Vietnam 01 Vo Van Ngan Street, Thu Duc Ward, Ho Chi Minh City, Vietnam<\/p>\n\n\n\n<p style=\"font-size:14px\"><sup>2<\/sup>Faculty of Industrial Engineering, Ben Tre Technology Post-Secondary School, Vietnam 899 National Road 57C, Son Dong Ward, Vinh Long Province, Vietnam<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-tkuwpbs5-bs5-div\" style=\"margin-top:var(--wp--preset--spacing--40)\" data-aos=\"normal\">\n<p>Received:&nbsp;December 26, 2025<br>Accepted:&nbsp;March 30, 2026<br>Publication Date:&nbsp;April 25, 2026<\/p>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-tkuwpbs5-bs5-column col-md-7 align-self-start clk=\u5716\u7247\"><img decoding=\"async\" src=\"\/jase\/wp-content\/uploads\/2026\/04\/32_017.jpg\" class=\"img-fluid img-fluid mx-auto d-block\" alt=\"\u4e0a\u50b3\u5716\u7247\">\n\n\n<p class=\"has-text-align-center img_caption\">The&nbsp;Simplified&nbsp;DC Distribution System.&nbsp;<\/p>\n<\/div>\n<\/div>\n\n\n\n<p class=\"has-small-font-size\"><i class=\"fab fa-creative-commons\"><\/i>&nbsp;<strong>Copyright&nbsp;<\/strong>The Author(s). This is an open access article distributed under the terms of the&nbsp;<a rel=\"noreferrer noopener\" href=\"https:\/\/creativecommons.org\/licenses\/by\/4.0\/\" target=\"_blank\">Creative Commons Attribution&nbsp;License (CC BY 4.0)<\/a>, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are cited.<\/p>\n\n\n\n<p>Download Citation:&nbsp; <a href=\"\/jase\/wp-content\/uploads\/2026\/04\/V32.017.bib\" data-type=\"attachment\" data-id=\"3864\" target=\"_blank\" rel=\"noreferrer noopener\">BibTeX <\/a>| <a rel=\"noreferrer noopener\" href=\"http:\/\/dx.doi.org\/10.6180\/jase.202609_32.017\" target=\"_blank\">http:\/\/dx.doi.org\/10.6180\/jase.202609_32.017<\/a>&nbsp;&nbsp;<\/p>\n\n\n\n<p class=\"btn btn-primary article-btn\"><a href=\"\/jase\/wp-content\/uploads\/2026\/04\/017_2025_2133_V32.pdf\" data-type=\"attachment\" data-id=\"3811\" target=\"_blank\" rel=\"noreferrer noopener\">Download PDF<\/a><\/p>\n\n\n\n<div style=\"height:24px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>In DC microgrids, Constant Power Load (CPL) is one of the causes to generate negative incremental resistance, which significantly reduces the stability margin and may lead to DC-bus voltage fluctuations. Therefore, the issue of handling the DC-bus voltage under the CPL is of considerable interest. In this paper, a Linear Extended State Observer-based Backstepping Sliding Mode Control (LESO-BSMC) strategy is proposed to enhance the robustness of output voltage for a boost converter under CPL and system uncertainties. A two-channel Linear Extended State Observer (LESO) is designed to estimate real-time disturbances caused by load variations, input-voltage fluctuations, and parameter mismatches, allowing for accurate compensation without relying on a detailed nonlinear model. The Backstepping Sliding Mode Control (BSMC) law is constructed based on the Lyapunov stability criteria to guarantee global stability, fast dynamic response, and reduced control chattering. Comprehensive simulations were conducted to confirm the effectiveness of the proposed algorithm for maintaining DC-bus voltage at 24 V under four scenarios. The obtained results demonstrate that the proposed LESO-BSMC strategy achieves high tracking performance, efficiency in disturbance rejection and robustness, faster dynamic recovery, and minimizes DC-bus voltage ripple in comparison to other strategies of PI-SMC and Adaptive BSMC (ABSMC), while significantly reducing switching activity as quantified by control-effort indices.<\/p>\n\n\n\n<p><em>Keywords:&nbsp;Constant Power Load, DC Microgrid, DC-Bus Voltage, Linear Extended State Observer, Sliding Mode Control.<\/em><\/p>\n\n\n\n<div style=\"height:2rem\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-tkuwpbs5-bs5-div ref_ol\" data-aos=\"normal\">\n<ol>\n<li>[1] M. Uddin, H. Mo, D. Dong, S. Elsawah, J. Zhu, and J. M. Guerrero, (2023) \u201cMicrogrids: A review, outstanding issues and future trends\u201d Energy Strategy Reviews 49: DOI: 10.1016\/j.esr.2023.101127.<\/li>\n<li>[2] C. N. Papadimitriou, E. I. Zountouridou, and N. D. Hatziargyriou, (2015) \u201cReview of hierarchical control in DC microgrids\u201d Electric Power Systems Research 122: 159\u2013167. DOI: 10.1016\/j.epsr.2015.01.006.<\/li>\n<li>[3] R. Kumar and C. N. Bhende, (2023) \u201cA virtual adaptive RC damper control method to suppress voltage oscillation in DC microgrid\u201d International Journal of Electrical Power &amp; Energy Systems 146: DOI: 10.1016\/j.ijepes.2022.108795.<\/li>\n<li>[4] E. Hossain, R. Perez, A. Nasiri, and S. Padmanaban, (2018) \u201cA Comprehensive Review on Constant Power Loads Compensation Techniques\u201d IEEE Access 6: 33285\u201333305. DOI: 10.1109\/access.2018.2849065.<\/li>\n<li>[5] S. Ansari, J. Zhang, and R. E. Singh, (2022) \u201cA review of stabilization methods for DCMG with CPL, the role of bandwidth limits and droop control\u201d Protection and Control of Modern Power Systems 7(1): DOI: 10.1186\/s41601-021-00222-x.<\/li>\n<li>[6] S. Liu, P. Su, and L. Zhang, (2018) \u201cA Virtual Negative Inductor Stabilizing Strategy for DC Microgrid With Constant Power Loads\u201d IEEE Access 6: 59728\u201359741. DOI: 10.1109\/access.2018.2874201.<\/li>\n<li>[7] Z. Zhang, G. Song, J. Zhou, X. Zhang, B. Yang, C. Liu, and J. M. Guerrero, (2022) \u201cAn adaptive backstepping control to ensure the stability and robustness for boost power converter in DC microgrids\u201d Energy Reports 8: 1110\u20131124. DOI: 10.1016\/j.egyr.2022.02.024.<\/li>\n<li>[8] H. Sira-Ramirez and M. Ilic-Spong, (1989) \u201cExact linearization in switched-mode DC-to-DC power converters\u201d International Journal of Control 50(2): 511\u2013524. DOI: 10.1080\/00207178908953380.<\/li>\n<li>[9] L. Wang, T. Miao, X. Liu, and S. Liu, (2020) \u201cSliding Mode Control of Bi-directional DC\/DC Converter in DC Microgrid Based on Exact Feedback Linearization\u201d Wseas Transactions on Circuits and Systems 19: 206\u2013211. DOI: 10.37394\/23201.2020.19.23.<\/li>\n<li>[10] K. E. Lucas, D. J. Pagano, D. A. Plaza, D. A. Vaca\u2013Benavides, and S. J. R\u00edos, (2020) \u201cRobust Feedback Linearization Control for DAB Converter feeding a CPL\u201d IFAC-PapersOnLine 53(2): 13402\u201313409. DOI: 10.1016\/j.ifacol.2020.12.178.<\/li>\n<li>[11] M. Csizmadia, M. Kuczmann, and T. Orosz, (2022) \u201cA Novel Control Scheme Based on Exact Feedback Linearization Achieving Robust Constant Voltage for Boost Converter\u201d Electronics 12(1): DOI: 10.3390\/electronics12010057.<\/li>\n<li>[12] J. D. Cham, F. L. D. Koffi, A. T. Boum, and A. Harrison, (2024) \u201cRobust adaptive sliding mode control of a bidirectional DC-DC converter feeding a resistive and CPL based on PSO\u201d International Journal of Power Electronics and Drive Systems (IJPEDS) 15(4): DOI: 10.11591\/ijpeds.v15.i4.pp2397-2408.<\/li>\n<li>[13] S. Zheng, M. Qi, Y. Shu, Y. Wang, and J. Lang, (2022) \u201cNon-singular terminal sliding mode control strategy for DC\/DC Boost converter system using a finite-time convergent observer\u201d IET Power Electronics 15(16): 1868\u20131876. DOI: 10.1049\/pel.2.12354.<\/li>\n<li>[14] S. Singh, D. Fulwani, and V. Kumar, (2015) \u201cRobust sliding-mode control of dc\/dc boost converter feeding a constant power load\u201d IET Power Electronics 8(7): 1230\u20131237. DOI: 10.1049\/iet-pel.2014.0534.<\/li>\n<li>[15] G. Mustafa, F. Ahmad, R. Zhang, E. U. Haq, and M. Hussain, (2023) \u201cAdaptive sliding mode control of buck converter feeding resistive and constant power load in DC microgrid\u201d Energy Reports 9: 1026\u20131035. DOI: 10.1016\/j.egyr.2022.11.131.<\/li>\n<li>[16] S. Oucheriah and L. Guo, (2013) \u201cPWM-Based Adaptive Sliding-Mode Control for Boost DC\u2013DC Converters\u201d IEEE Transactions on Industrial Electronics 60(8): 3291\u20133294. DOI: 10.1109\/tie.2012.2203769.<\/li>\n<li>[17] Z. Alam, T. K. Roy, S. K. Ghosh, and M. A. Mahmud, (2023) \u201cA hybrid non-linear voltage controller design for DC\u2013DC buck converters\u201d The Journal of Engineering 2023(10): DOI: 10.1049\/tje2.12318.<\/li>\n<li>[18] J. Linares-Flores, J. A. Juarez-Abad, A. Hernandez-Mendez, O. Castro-Heredia, J. F. Guerrero-Castellanos, R. Heredia-Barba, and G. Curiel-Olivares, (2022) \u201cSliding Mode Control Based on Linear Extended State Observer for DC-to-DC Buck-Boost Power Converter System With Mismatched Disturbances\u201d IEEE Transactions on Industry Applications 58(1): 940\u2013950. DOI: 10.1109\/tia.2021.3130017.<\/li>\n<li>[19] R. F. Muktiadji, M. A. M. Ramli, H. R. E. H. Bouchekara, A. H. Milyani, M. Rawa, M. M. A. Seedahmed, and F. N. Budiman, (2022) \u201cControl of Boost Converter Using Observer-Based Backstepping Sliding Mode Control for DC Microgrid\u201d Frontiers in Energy Research 10: DOI: 10.3389\/fenrg.2022.828978.<\/li>\n<li>[20] D. J. Almakhles, (2020) &#8220;Robust Backstepping Sliding Mode Control for a Quadrotor Trajectory Tracking Application&#8221; IEEE Access 8: 5515\u20135525. DOI: 10.1109\/access.2019.2962722.<\/li>\n<li>[21] T. K. Roy, S. K. Ghosh, and S. Saha, (2023) &#8220;Robust backstepping global integral terminal sliding mode controller to enhance dynamic stability of hybrid AC\/DC microgrids&#8221; Protection and Control of Modern Power Systems 8(1): DOI: 10.1186\/s41601-023-00281-2.<\/li>\n<li>[22] J. Wu and Y. Lu, (2019) &#8220;Adaptive Backstepping Sliding Mode Control for Boost Converter With Constant Power Load&#8221; IEEE Access 7: 50797\u201350807. DOI: 10.1109\/access.2019.2910936.<\/li>\n<li>[23] Z. Karami, Q. Shafiee, S. Sahoo, M. Yaribeygi, H. Bevrani, and T. Dragicevic, (2021) &#8220;Hybrid Model Predictive Control of DC-DC Boost Converters With Constant Power Load&#8221; IEEE Transactions on Energy Conversion 36(2): 1347\u20131356. DOI: 10.1109\/tec.2020.3047754.<\/li>\n<li>[24] M. A. Hassan, C.-L. Su, J. Pou, G. Sulligoi, D. Almakhles, D. Bosich, and J. M. Guerrero, (2022) &#8220;DC Shipboard Microgrids With Constant Power Loads: A Review of Advanced Nonlinear Control Strategies and Stabilization Techniques&#8221; IEEE Transactions on Smart Grid 13(5): 3422\u20133438. DOI: 10.1109\/tsg.2022.3168267.<\/li>\n<li>[25] S. Vazquez, J. Rodriguez, M. Rivera, L. G. Franquelo, and M. Norambuena, (2017) &#8220;Model Predictive Control for Power Converters and Drives: Advances and Trends&#8221; IEEE Transactions on Industrial Electronics 64(2): 935\u2013947. DOI: 10.1109\/tie.2016.2625238.<\/li>\n<li>[26] S. Oucheriah and A. Azad, (2024) &#8220;Robust Nonlinear Current Sensorless Control of the Boost Converter with Constant Power Load&#8221; Circuits and Systems 15(03): 29\u201343. DOI: 10.4236\/cs.2024.153003.<\/li>\n<li>[27] J.-H. Xu, B.-X. Zhang, H.-Z. Yan, Q. Ding, K.-Q. Zhu, Y.-R. Yang, T.-M. Huang, S. Li, Z.-M. Wan, and X.-D. Wang, (2024) &#8220;Sliding mode \u2013 Extended state observer control strategy to improve energy transfer of PEMFC connected DC-DC boost converter system&#8221; Sustainable Energy Technologies and Assessments 63: DOI: 10.1016\/j.seta.2024.103654.<\/li>\n<li>[28] M. Yang and P. Liu, (2023) &#8220;Research on Sliding Mode Control of Dual Active Bridge Converter Based on Linear Extended State Observer in Distributed Electric Propulsion System&#8221; Electronics 12(16): DOI: 10.3390\/electronics12163522.<\/li>\n<li>[29] A. Viswambharan, R. Errouissi, M. Debouza, and H. Shareef, (2023) &#8220;Experimental Verification of Disturbance Observer-Based Backstepping Control for DC-DC Boost Converter&#8221; IEEE Transactions on Circuits and Systems I: Regular Papers 70(12): 5520\u20135533. DOI: 10.1109\/tcsi.2023.3318970.<\/li>\n<li>[30] Z. Tian, R. Ren, and D. Tian. A Extended State Observer Based Backstepping Control for Improving Stability of DC-DC Boost Converters with Constant Power Loads. Conference Paper. 2024. DOI: 10.1109\/ei264398.2024.10991407.<\/li>\n<li>[31] Q. Xu, C. Zhang, C. Wen, and P. Wang, (2019) &#8220;A Novel Composite Nonlinear Controller for Stabilization of Constant Power Load in DC Microgrid&#8221; IEEE Transactions on Smart Grid 10(1): 752\u2013761. DOI: 10.1109\/tsg.2017.2751755.<\/li>\n<li>[32] M. Alipour, J. Zarei, R. Razavi-Far, M. Saif, N. Mijatovic, and T. Dragicevic, (2023) &#8220;Observer-Based Backstepping Sliding Mode Control Design for Microgrids Feeding a Constant Power Load&#8221; IEEE Transactions on Industrial Electronics 70(1): 465\u2013473. DOI: 10.1109\/tie.2022.3152028.<\/li>\n<li>[33] J.-Q. Han. &#8220;Nonlinear design methods for control systems&#8221;. In: IFAC Proceedings Volumes. 32. 1999, 1531\u20131536. DOI: 10.1016\/s1474-6670(17)56259-x.<\/li>\n<li>[34] J. Han, (2009) &#8220;From PID to Active Disturbance Rejection Control&#8221; IEEE Transactions on Industrial Electronics 56(3): 900\u2013906. DOI: 10.1109\/tie.2008.2011621.<\/li>\n<li>[35] Z. Gao. &#8220;Scaling and bandwidth-parameterization based controller tuning&#8221;. In: the 2003 American Control Conference. IEEE, 2003, 4989\u20134996. DOI: 10.1109\/ACC.2003.1242516.<\/li>\n<li>[36] Z. S. Zhiqiang and G. &#8220;Active disturbance rejection control for nonminimum phase systems&#8221;. In: the 29th Chinese Control Conference. IEEE, 2010, 6066\u20136070. URL: <a class=\"ng-star-inserted\" href=\"https:\/\/www.google.com\/search?q=https:\/\/ieeexplore.ieee.org\/document\/5572904\" target=\"_blank\" rel=\"noopener\">https:\/\/ieeexplore.ieee.org\/document\/5572904<\/a>.<\/li>\n<li>[37] J. Esp\u00edn, F. Castrillon, H. Leiva, and O. Camacho, (2022) &#8220;A modified Smith predictor based \u2013 Sliding mode control approach for integrating processes with dead time&#8221; Alexandria Engineering Journal 61(12): 10119\u201310137. DOI: 10.1016\/j.aej.2022.03.045.<\/li>\n<li>[38] M. C. Maya-Rodriguez, I. Carvajal-Mariscal, R. L\u00f3pez-Mu\u00f1oz, M. A. Lopez-Pacheco, and R. Tolentino-Eslava, (2023) &#8220;Temperature Control of a Chemical Reactor Based on Neuro-Fuzzy Tuned with a Metaheuristic Technique to Improve Biodiesel Production&#8221; Energies 16(17): DOI: 10.3390\/en16176187.<\/li>\n<li>[39] C. Obando, R. Rojas, F. Ulloa, and O. Camacho, (2023) \u201cDual-Mode Based Sliding Mode Control Approach for Nonlinear Chemical Processes&#8221; ACS Omega 8(10): 9511\u20139525. DOI: 10.1021\/acsomega.2c08201. URL: https:\/\/www.ncbi.nlm.nih.gov\/pubmed\/36936305.<\/li>\n<\/ol>\n<\/div>\n\n\n\n<p><\/p>\n","protected":false},"author":3,"template":"wp-custom-template-detail-4-aricles","meta":{"_uag_custom_page_level_css":""},"categories":[12,720,6],"tags":[737],"acf":[],"uagb_featured_image_src":[],"uagb_author_info":{"display_name":"\u6797\u923a\u6db5","author_link":"\/jase\/?author=3"},"uagb_comment_info":0,"uagb_excerpt":"&nbsp;Copyright&nbsp;The Author(s). This is an open access article distributed under the terms of the&nbsp;Creative Commons Attribution&nbsp;License (CC BY 4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are cited. Download Citation:&nbsp; BibTeX | http:\/\/dx.doi.org\/10.6180\/jase.202609_32.017&nbsp;&nbsp; Download PDF In DC microgrids, Constant Power Load (CPL) is one of the&hellip;","_links":{"self":[{"href":"\/jase\/index.php?rest_route=\/wp\/v2\/tkuisotope\/3835"}],"collection":[{"href":"\/jase\/index.php?rest_route=\/wp\/v2\/tkuisotope"}],"about":[{"href":"\/jase\/index.php?rest_route=\/wp\/v2\/types\/tkuisotope"}],"author":[{"embeddable":true,"href":"\/jase\/index.php?rest_route=\/wp\/v2\/users\/3"}],"wp:attachment":[{"href":"\/jase\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=3835"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"\/jase\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=3835"},{"taxonomy":"post_tag","embeddable":true,"href":"\/jase\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=3835"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}