{"id":2814,"date":"2026-04-06T17:02:55","date_gmt":"2026-04-06T09:02:55","guid":{"rendered":"https:\/\/iweb20wp-b205b.url.tku.edu.tw\/jase\/?post_type=tkuisotope&#038;p=2814"},"modified":"2026-06-07T14:10:22","modified_gmt":"2026-06-07T06:10:22","slug":"wearable-fbg-strain-flexibility-in-supplemental-oxygenassisted-respiratory-examination","status":"publish","type":"tkuisotope","link":"\/jase\/?tkuisotope=wearable-fbg-strain-flexibility-in-supplemental-oxygenassisted-respiratory-examination","title":{"rendered":"Wearable FBG strain flexibility in supplemental oxygenassisted respiratory examination"},"content":{"rendered":"\n<div class=\"wp-block-tkuwpbs5-bs5-row row article-info\">\n<div class=\"wp-block-tkuwpbs5-bs5-column col-md-3 align-self-start\">\n<p><i class=\"fa fa-folder\" aria-hidden=\"true\"><\/i>&nbsp;<a href=\"\/jase\/?page_id=2115\" data-type=\"page\" data-id=\"807\">2025<\/a><\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-tkuwpbs5-bs5-column col-md-3 align-self-start\">\n<p><i class=\"fa fa-folder-open\" aria-hidden=\"true\"><\/i>&nbsp;<a href=\"\/jase\/?page_id=2769\" data-type=\"page\" data-id=\"1055\">Volume 28, Issue 11<\/a><\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-tkuwpbs5-bs5-column col-md-6 align-self-start\">\n<div class=\"wp-block-tkuwpbs5-bs5-div dv_publish\" data-aos=\"normal\"><div class=\"wp-block-post-date\"><time datetime=\"2026-04-06T17:02:55+08:00\">2026-04-06<\/time><\/div><\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-tkuwpbs5-bs5-row row\">\n<div class=\"wp-block-tkuwpbs5-bs5-column col-md-5 align-self-start\">\n<div class=\"wp-block-tkuwpbs5-bs5-div au-ol\" data-aos=\"normal\">\n<p>Saktioto<sup>1<\/sup><a href=\"mailto:saktioto@lecturer.unri.ac.id\"><i class=\"fa fa-envelope\"><\/i><\/a>, Anisa Alya Syafri<sup>1<\/sup>, Mulhida<sup>1<\/sup>, Bambang Widiyatmoko<sup>2<\/sup>, Dwi Hanto<sup>2<\/sup>, Yan Soerbakti<sup>1<\/sup>, Reeky Fardinata<sup>1<\/sup>, Okfalisa<sup>3<\/sup>, Dedi Irawan<sup>4<\/sup>, and Rina Amelia<sup>5<\/sup><\/p>\n\n\n\n<p style=\"font-size:14px\"><sup>1<\/sup>Department of Physics, Universitas Riau, Pekanbaru 28293, Indonesia<\/p>\n\n\n\n<p style=\"font-size:14px\"><sup>2<\/sup>Research Center for Photonics, KST BJ HABIBIE, South Tangerang 15314, Indonesia<\/p>\n\n\n\n<p style=\"font-size:14px\"><sup>3<\/sup>Department of Informatics Engineering, UIN Sultan Syarif Kasim, Pekanbaru 28293, Indonesia<\/p>\n\n\n\n<p style=\"font-size:14px\"><sup>4<\/sup>Department of Physics Education, Universitas Riau, Pekanbaru 28293, Indonesia<\/p>\n\n\n\n<p style=\"font-size:14px\"><sup>5<\/sup>Department of Community Medicine, Universitas Sumatera Utara, Medan 20155, Indonesia<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-tkuwpbs5-bs5-div\" style=\"margin-top:var(--wp--preset--spacing--40)\" data-aos=\"normal\">\n<p>Received:&nbsp;February 29, 2024<br>Accepted:&nbsp;November 1, 2024<br>Publication Date:&nbsp;April 6, 2026<\/p>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-tkuwpbs5-bs5-column col-md-7 align-self-start clk=\u5716\u7247\"><img decoding=\"async\" src=\"\/jase\/wp-content\/uploads\/2026\/04\/28_11_05.jpg\" class=\"img-fluid img-fluid mx-auto d-block\" alt=\"\u4e0a\u50b3\u5716\u7247\">\n\n\n<p class=\"has-text-align-center\">FBG strain based on its position in the mask for the four objects under normal breathing conditions.<\/p>\n<\/div>\n<\/div>\n\n\n\n<p class=\"has-small-font-size\"><i class=\"fab fa-creative-commons\"><\/i>&nbsp;<strong>Copyright&nbsp;<\/strong>The Author(s). This is an open access article distributed under the terms of the&nbsp;<a rel=\"noreferrer noopener\" href=\"https:\/\/creativecommons.org\/licenses\/by\/4.0\/\" target=\"_blank\">Creative Commons Attribution&nbsp;License (CC BY 4.0)<\/a>, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are cited.<\/p>\n\n\n\n<p>Download Citation:\u00a0 <a href=\"\/jase\/wp-content\/uploads\/2026\/06\/V2811.0005.bib\" data-type=\"attachment\" data-id=\"7677\" target=\"_blank\" rel=\"noreferrer noopener\">BibTeX <\/a>| <a rel=\"noreferrer noopener\" href=\"http:\/\/dx.doi.org\/10.6180\/jase.202511_28(11).0005\" target=\"_blank\">http:\/\/dx.doi.org\/10.6180\/jase.202511_28(11).0005<\/a>\u00a0\u00a0<\/p>\n\n\n\n<p class=\"btn btn-primary article-btn\"><a href=\"\/jase\/wp-content\/uploads\/2026\/04\/05_2024_0283_V28i11.pdf\" data-type=\"attachment\" data-id=\"2795\" target=\"_blank\" rel=\"noreferrer noopener\">Download PDF<\/a><\/p>\n\n\n\n<div style=\"height:24px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>Subtle sensing is one of the important aspects required in the performance of modern medical technology, especially the detection of elusive human respiratory risks. In this regard, the fiber Bragg grating (FBG) sensor offers a high-sensitivity measurement of supplemental oxygen-assisted human respiratory characteristics through a strain approach. The FBG wavelength of 1550 nm is induced by nasal airflow and back-body surface on resting and active objects. The treated FBG will undergo deformation resulting in a change in the Bragg wavelength, which is then measured using an optical sensing interrogator and processed to obtain the strain value. The measurement results show significant FBG strain values at the micro-scale. The addition of oxygen flow in the body can increase the stretch that occurs during breathing. Therefore, the FBG sensor is more effectively used in conditions with the addition of oxygen flow.<\/p>\n\n\n\n<p><em>Keywords:&nbsp;Fiber Bragg grating; oxygen flow; respiratory; strain<\/em><\/p>\n\n\n\n<div style=\"height:2rem\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-tkuwpbs5-bs5-div ref_ol\" data-aos=\"normal\">\n<ol>\n<li>[1] W.-H. Shi, W.-M. Lv, T.-Y. Sun, and B.-S. Zhang, (2019) \u201cOptoelectronic platform and technology&#8221; Frontiers of Information Technology and Electronic Engineering 20: 439\u2013457. DOI: 10.1631\/FITEE.1800451.<\/li>\n<li>[2] D. Tosi, E. Schena, C. Molardi, and S. Korganbayev, (2018) \u201cFiber optic sensors for sub-centimeter spatially resolved measurements: Review and biomedical applications&#8221; Optical Fiber Technology 43: 6\u201319. DOI: 10.1016\/j.yofte.2018.03.007.<\/li>\n<li>[3] L. Dziuda, J. Lewandowski, F. Skibniewski, and G. Nowicki, (2012) \u201cFibre-optic sensor for respiration and heart rate monitoring in the MRI environment&#8221; Procedia Engineering 47: 1291\u20131294. DOI: 10.1016\/j.proeng.2012.09.391.<\/li>\n<li>[4] A. Leal-Junior, C. Marques, and A. Frizera, (2022) \u201cDiaphragm-assisted impact amplitude and localization measurement system with FBG sensors&#8221; Optical Fiber Technology 70: 102854. DOI: 10.1016\/j.yofte.2022.102854.<\/li>\n<li>[5] J. Yu, C. Li, X. Qiu, and H. Chen, (2021) \u201cA full-optical strain FBG sensor for in-situ monitoring of fatigue stages via tunable DFB laser demodulation&#8221; Optical and Quantum Electronics 53: 1\u201312. DOI: 10.1007\/s11082-021-02800-7.<\/li>\n<li>[6] P. Hariprasad, C. Chanchal, P. Anita, G. Arun, and S. Sandeep, (2023) \u201cDevelopment of a prototype fiber-optic biosensor for the detection of lipase inhibitors&#8221; Kuwait Journal of Science 50: 333\u2013338. DOI: 10.1016\/j.kjs.2023.05.009.<\/li>\n<li>[7] T. Saktioto, F. D. Fadilla, Y. Soerbakti, and D. Irawan, (2021) \u201cApplication of fiber Bragg grating sensor system for simulation detection of the heart rate&#8221; Journal of Physics: Conference Series 2049: 012002. DOI: 10.1088\/1742-6596\/2049\/1\/012002.<\/li>\n<li>[8] H. Z. Yang, S. W. Harun, and H. Ahmad, (2011) \u201cTheoretical and experimental studies on concave mirror-based fiber optic displacement sensor&#8221; Sensor Review 31: 65\u201369. DOI: 10.1108\/02602281111099107.<\/li>\n<li>[9] C. Hong, Y. Yuan, Y. Yang, Y. Zhang, and Z. A. Abro, (2019) \u201cA simple FBG pressure sensor fabricated using fused deposition modelling process&#8221; Sensors and Actuators A: Physical 285: 269\u2013274. DOI: 10.1016\/j.sna.2018.11.024.<\/li>\n<li>[10] C. Hong, Y. Zhang, and L. Borana, (2019) \u201cDesign, fabrication and testing of a 3D printed FBG pressure sensor&#8221; IEEE Access 7: 38577\u201338583. DOI: 10.1109\/ACCESS.2019.2905349.<\/li>\n<li>[11] N. A. Rosman, C. B. M. Rashidi, S. A. Aljunid, and R. Endut, (2020) \u201cTemperature monitoring system using fiber Bragg grating (FBG) approach&#8221; AIP Conference Proceedings 2203: 020065. DOI: 10.1063\/1.5142157.<\/li>\n<li>[12] X. Wang, Y. Jiang, S. Xu, H. Liu, and X. Li, (2022) \u201cFiber Bragg grating-based smart garment for monitoring human body temperature&#8221; Sensors 22: 4252. DOI: 10.3390\/s22114252.<\/li>\n<li>[13] T. Saktioto, Y. Soerbakti, A. Thoibah, B. Meyzia, R. F. Syahputra, D. Irawan, and H. Hairi, (2023) \u201cNumerical investigation of physical parameters in cardiac vessels as a new medical support science for complex blood flow characteristics&#8221; Baghdad Science Journal 20: 2322\u20132329. DOI: 10.21123\/bsj.2023.7076.<\/li>\n<li>[14] Defrianto, T. Saktioto, N. Hikma, Y. Soerbakti, D. Irawan, Okfalisa, B. Widiyatmoko, and D. Hanto, (2022) \u201cExternal perspective of lung airflow model through diaphragm breathing sensor using fiber optic elastic belt&#8221; Indian Journal of Pure and Applied Physics 60: 561\u2013566. DOI: 10.56042\/ijpap.v60i7.62342.<\/li>\n<li>[15] S. Saktioto, D. Defrianto, A. Thoibah, Y. Soerbakti, R. F. Syahputra, S. Syamsudhuha, D. Irawan, H. Hairi, O. Okfalisa, and R. Amelia, (2023) \u201cSimplified kinetic model of heart pressure for human dynamical blood flow&#8221; Indonesian Journal of Electrical Engineering and Informatics 11: 870\u2013882. DOI: 10.52549\/ijeei.v11i3.3473.<\/li>\n<li>[16] T. Saktioto, D. Defrianto, N. Hikma, Y. Soerbakti, S. Syamsudhuha, D. Irawan, O. Okfalisa, B. Widiyatmoko, and D. Hanto, (2022) \u201cAirflow vibration of diaphragmatic breathing: model and demonstration using optical biosensor&#8221; Telkomnika (Telecommunication Computing Electronics and Control) 21: 667\u2013674. DOI: 10.12928\/TELKOMNIKA.v21i3.23613.<\/li>\n<li>[17] N. Hikma, T. Saktioto, and Y. Soerbakti, (2023) \u201cVibration analysis of diaphragmatic breathing activity using single-mode fiber and fiber Bragg grating&#8221; AIP Conference Proceedings 2858: 080001. DOI: 10.1063\/5.0163142.<\/li>\n<li>[18] H. A. Mohammed and M. H. Yaacob, (2020) \u201cA novel modified fiber Bragg grating (FBG) based ammonia sensor coated with polyaniline\/graphite nanofibers nanocomposites&#8221; Optical Fiber Technology 58: 102282. DOI: 10.1016\/j.yofte.2020.102282.<\/li>\n<li>[19] Z. Ruan, L. Pei, T. Ning, J. Wang, J. Wang, J. Li, Y. Xie, Q. Zhao, and J. Zheng, (2021) \u201cSimple structure of tapered FBG filled with magnetic fluid to realize magnetic field sensor&#8221; Optical Fiber Technology 67: 102698. DOI: 10.1016\/j.yofte.2021.102698.<\/li>\n<li>[20] C. Cui, L. Gao, N. Dai, and Q. Xu, (2021) \u201cFiber Bragg grating inclinometer-enabled IoT sensing system with low power consumption and small size&#8221; Sensors and Materials 33: 2321\u20132331. DOI: 10.18494\/SAM.2021.3281.<\/li>\n<li>[21] X. Li, Y. Yang, W. Zhang, Z. Wang, Y. Yuan, H. Hu, and D. Xu, (2021) \u201cAn FBG pressure sensor based on spring-diaphragm elastic structure for ultimate pressure detection&#8221; IEEE Sensors Journal 22: 2213\u20132220. DOI: 10.1109\/JSEN.2021.3136212.<\/li>\n<li>[22] Y. He, Q. Yang, S. Sun, M. Luo, R. Liu, and G.-D. Peng, (2020) \u201cA multi-point voltage sensing system based on PZT and FBG&#8221; International Journal of Electrical Power and Energy Systems 117: 105607. DOI: 10.1016\/j.ijepes.2019.105607.<\/li>\n<li>[23] J. K. Sahota, N. Gupta, and D. Dhawan, (2020) \u201cFiber Bragg grating sensors for monitoring of physical parameters: A comprehensive review&#8221; Optical Engineering 59: 060901. DOI: 10.1117\/1.oe.59.6.060901.<\/li>\n<li>[24] C. Tavares, C. Leit\u00e3o, D. L. Presti, M. F. Domingues, N. Alberto, H. Silva, and P. Antunes, (2022) \u201cRespiratory and heart rate monitoring using an FBG 3D-printed wearable system&#8221; Biomedical Optics Express 13: 2299\u20132311. DOI: 10.1364\/boe.452115.<\/li>\n<li>[25] M. Filosa, L. Massari, D. Ferraro, G. D\u2019Alesio, J. D\u2019Abbraccio, A. Aliperta, D. L. Presti, J. D. Tocco, M. Zaltieri, C. Massaroni, M. C. Carrozza, M. Ferrarin, M. D. Rienzo, E. Schena, and C. M. Oddo, (2022) \u201cA meta-learning algorithm for respiratory flow prediction from FBG-based wearables in unrestrained conditions&#8221; Artificial Intelligence in Medicine 130: 102328. DOI: 10.1016\/j.artmed.2022.102328.<\/li>\n<li>[26] W. Chen, J. Wang, F. Wan, and P. Wang, (2019) \u201cReview of optical fibre sensors for electrical equipment characteristic state parameters detection&#8221; High Voltage 4: 271\u2013281. DOI: 10.1049\/hve.2019.0157.<\/li>\n<li>[27] V. Mishra, N. Singh, U. Tiwari, and P. Kapur, (2011) \u201cFiber grating sensors in medicine: Current and emerging applications&#8221; Sensors and Actuators A: Physical 167: 279\u2013290. DOI: 10.1016\/j.sna.2011.02.045.<\/li>\n<li>[28] C. E. Campanella, A. Cuccovillo, C. Campanella, A. Yurt, and V. M. N. Passaro, (2018) \u201cFibre Bragg grating based strain sensors: Review of technology and applications&#8221; Sensors 18: 3115. DOI: 10.3390\/s18093115.<\/li>\n<li>[29] R. Li, Y. Chen, Y. Tan, Z. Zhou, T. Li, and J. Mao, (2018) \u201cSensitivity enhancement of FBG-based strain sensor&#8221; Sensors 18: 1607. DOI: 10.3390\/s18051607.<\/li>\n<li>[30] M. S. Siobal, (2016) \u201cMonitoring exhaled carbon dioxide&#8221; Respiratory Care 61: 1397\u20131416. DOI: 10.4187\/respcare.04919.<\/li>\n<li>[31] A. Issatayeva, A. Beisenova, D. Tosi, and C. Molardi, (2021) \u201cFiber-optic based wearables for the continuous monitoring of respiratory rate&#8221; Biophotonics in Exercise Science, Sports Medicine, Health Monitoring Technologies, and Wearables II 11638: 1163805. DOI: 10.1117\/12.2582461.<\/li>\n<li>[32] C. Shi, Z. Tang, H. Zhang, and Y. Liu, (2023) \u201cDevelopment of an FBG-based wearable sensor for simultaneous respiration and heartbeat measurement&#8221; IEEE Transactions on Instrumentation and Measurement 72: 1\u20139. DOI: 10.1109\/TIM.2022.3228276.<\/li>\n<li>[33] J. Zhang, Z. Lian, Z. Zhou, Z. Song, M. Liu, and K. Yang, (2022) \u201cLeakage detection in a buried gas pipeline based on distributed optical fiber time-domain acoustic wave signal&#8221; Engineering Failure Analysis 141: 106594. DOI: 10.1016\/j.engfailanal.2022.106594.<\/li>\n<li>[34] J. G\u00f3mez, J. R. Casas, and S. Villalba, (2020) \u201cStructural health monitoring with distributed optical fiber sensors of tunnel lining affected by nearby construction activity&#8221; Automation in Construction 117: 103261. DOI: 10.1016\/j.autcon.2020.103261.<\/li>\n<li>[35] H. Merdji, A. Curtiaud, A. Aheto, A. Studer, V.-P. Harjola, A. Monnier, K. Duarte, N. Girerd, M. Kibler, H. Ait-Oufella, J. Helms, A. Mebazaa, B. Levy, A. Kimmoun, and F. Meziani, (2022) \u201cPerformance of early capillary refill time measurement on outcomes in cardiogenic shock: An observational, prospective multicentric study&#8221; American Journal of Respiratory and Critical Care Medicine 206: 1230\u20131238. DOI: 10.1164\/rccm.202204-0687OC.<\/li>\n<li>[36] R. Min, X. Hu, L. Pereira, S. Soares, L. C. B. Silva, G. Wang, L. Martins, H. Qu, P. Antunes, C. Marques, and X. Li, (2022) \u201cPolymer optical fiber for monitoring human physiological and body function: A comprehensive review on mechanisms, materials, and applications&#8221; Optics and Laser Technology 147: 107626. DOI: 10.1016\/j.optlastec.2021.107626.<\/li>\n<\/ol>\n<\/div>\n\n\n\n<p><\/p>\n","protected":false},"author":3,"template":"wp-custom-template-detail-4-aricles","meta":{"_uag_custom_page_level_css":""},"categories":[9,6,274],"tags":[479],"acf":[],"uagb_featured_image_src":[],"uagb_author_info":{"display_name":"\u6797\u923a\u6db5","author_link":"\/jase\/?author=3"},"uagb_comment_info":0,"uagb_excerpt":"&nbsp;Copyright&nbsp;The Author(s). This is an open access article distributed under the terms of the&nbsp;Creative Commons Attribution&nbsp;License (CC BY 4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are cited. Download Citation:\u00a0 BibTeX | http:\/\/dx.doi.org\/10.6180\/jase.202511_28(11).0005\u00a0\u00a0 Download PDF Subtle sensing is one of the important aspects required in the&hellip;","_links":{"self":[{"href":"\/jase\/index.php?rest_route=\/wp\/v2\/tkuisotope\/2814"}],"collection":[{"href":"\/jase\/index.php?rest_route=\/wp\/v2\/tkuisotope"}],"about":[{"href":"\/jase\/index.php?rest_route=\/wp\/v2\/types\/tkuisotope"}],"author":[{"embeddable":true,"href":"\/jase\/index.php?rest_route=\/wp\/v2\/users\/3"}],"wp:attachment":[{"href":"\/jase\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=2814"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"\/jase\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=2814"},{"taxonomy":"post_tag","embeddable":true,"href":"\/jase\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=2814"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}