{"id":2236,"date":"2026-04-03T16:10:17","date_gmt":"2026-04-03T08:10:17","guid":{"rendered":"https:\/\/iweb20wp-b205b.url.tku.edu.tw\/jase\/?post_type=tkuisotope&#038;p=2236"},"modified":"2026-05-24T14:14:36","modified_gmt":"2026-05-24T06:14:36","slug":"analyzing-glass-configurations-for-energy-efficiency-in-building-envelopes-a-comparative","status":"publish","type":"tkuisotope","link":"\/jase\/?tkuisotope=analyzing-glass-configurations-for-energy-efficiency-in-building-envelopes-a-comparative","title":{"rendered":"Analyzing Glass Configurations For Energy Efficiency In Building Envelopes: A Comparative"},"content":{"rendered":"\n<div class=\"wp-block-tkuwpbs5-bs5-row row article-info\">\n<div class=\"wp-block-tkuwpbs5-bs5-column col-md-3 align-self-start\">\n<p><i class=\"fa fa-folder\" aria-hidden=\"true\"><\/i>&nbsp;<a href=\"\/jase\/?page_id=2115\" data-type=\"page\" data-id=\"807\">2025<\/a><\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-tkuwpbs5-bs5-column col-md-3 align-self-start\">\n<p><i class=\"fa fa-folder-open\" aria-hidden=\"true\"><\/i>&nbsp;<a href=\"\/jase\/?page_id=2223\" data-type=\"page\" data-id=\"1055\">Volume 28, Issue 2<\/a><\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-tkuwpbs5-bs5-column col-md-6 align-self-start\">\n<div class=\"wp-block-tkuwpbs5-bs5-div dv_publish\" data-aos=\"normal\"><div class=\"wp-block-post-date\"><time datetime=\"2026-04-03T16:10:17+08:00\">2026-04-03<\/time><\/div><\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-tkuwpbs5-bs5-row row\">\n<div class=\"wp-block-tkuwpbs5-bs5-column col-md-5 align-self-start\">\n<div class=\"wp-block-tkuwpbs5-bs5-div au-ol\" data-aos=\"normal\">\n<p>Muhammad Tayyab Naqash<a href=\"mailto:engr.tayyabnaqash@gmail.com\"><i class=\"fa fa-envelope\"><\/i><\/a><\/p>\n\n\n\n<p style=\"font-size:14px\">Department of Civil Engineering, Faculty of Engineering, Islamic University of Madinah, Kingdom of Saudi Arabia<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-tkuwpbs5-bs5-div\" style=\"margin-top:var(--wp--preset--spacing--40)\" data-aos=\"normal\">\n<p>Received:&nbsp;October 06, 2023<br>Accepted:&nbsp;November 27, 2023<br>Publication Date:&nbsp;April 3, 2026<\/p>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-tkuwpbs5-bs5-column col-md-7 align-self-start clk=\u5716\u7247\"><img decoding=\"async\" src=\"\/jase\/wp-content\/uploads\/2026\/04\/28_02_11.jpg\" class=\"img-fluid img-fluid mx-auto d-block\" alt=\"\u4e0a\u50b3\u5716\u7247\">\n\n\n<p class=\"has-text-align-center\">Comparison of R-value for Case 2 (Double clear) and Case 3 (Double low-e) glass.<\/p>\n<\/div>\n<\/div>\n\n\n\n<p class=\"has-small-font-size\"><i class=\"fab fa-creative-commons\"><\/i>&nbsp;<strong>Copyright&nbsp;<\/strong>The Author(s). This is an open access article distributed under the terms of the&nbsp;<a rel=\"noreferrer noopener\" href=\"https:\/\/creativecommons.org\/licenses\/by\/4.0\/\" target=\"_blank\">Creative Commons Attribution&nbsp;License (CC BY 4.0)<\/a>, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are cited.<\/p>\n\n\n\n<p>Download Citation:\u00a0 <a href=\"\/jase\/wp-content\/uploads\/2026\/05\/V282.0011.bib\" data-type=\"attachment\" data-id=\"7185\" target=\"_blank\" rel=\"noreferrer noopener\">BibTeX <\/a>| <a rel=\"noreferrer noopener\" href=\"http:\/\/dx.doi.org\/10.6180\/jase.202502_28(2).0011\" target=\"_blank\">http:\/\/dx.doi.org\/10.6180\/jase.202502_28(2).0011<\/a>\u00a0\u00a0<\/p>\n\n\n\n<p class=\"btn btn-primary article-btn\"><a href=\"\/jase\/wp-content\/uploads\/2026\/04\/11_2023_1171_V28i2.pdf\" data-type=\"attachment\" data-id=\"2192\" target=\"_blank\" rel=\"noreferrer noopener\">Download PDF<\/a><\/p>\n\n\n\n<div style=\"height:24px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>As the climate of the globe changes, buildings will need to accommodate new standards for typical and extreme weather. Glass configurations may help adapt structures to these changing climates. The most important features of several glass configurations for energy-efficient buildings are compared in this work. Thermal performance, light transmission, solar heat gain coefficient, sound reduction, structural and mechanical strength, and other factors were considered while evaluating glass configurations. The findings show that glass combinations with higher R-values and lower U-values offer excellent thermal insulation and are advised for high thermal requirements. Conversely, those with higher U-values and lower R-values best serve interior applications with low to moderate thermal demands. Considerations like light transmission, solar heat gain coefficient, sound reduction, structural strength, and mechanical strength can help narrow the options for optimum glass configuration for a particular application. Choosing the appropriate glass arrangement requires careful consideration of several factors to produce an indoor atmosphere that is secure, safe, pleasant, and energy efficient.<\/p>\n\n\n\n<p><em>Keywords:&nbsp;Glass; Energy Efficiency; Thermal Performance; Light Transmission; Sound Reduction; Structural Strength<\/em><\/p>\n\n\n\n<div style=\"height:2rem\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-tkuwpbs5-bs5-div ref_ol\" data-aos=\"normal\">\n<ol>\n<li>[1] M. T. Naqash et al., (2021) \u201cAssessment of rigid steel frames: Ductility versus damageability&#8221; Journal of Applied Science and Engineering 24(6): 915\u2013926. DOI: 10.6180\/jase.202112_24(6).0012.<\/li>\n<li>[2] F. B. Ola, N. Sekarlangit, B. Michelle, M. D. K. A. Anindita, F. U. Setyaningfebry, et al., (2021) \u201cHeat Transfer in the Universal Form of High-rise Buildings in Various Climate Zones&#8221; Journal of Applied Science and Engineering 25(1): 187\u2013194. DOI: 10.6180\/jase.202202_25(1).0019.<\/li>\n<li>[3] M. T. Naqash, A. Formisano, and E. Noroozinejad Farsangi, (2022) \u201cUsing a Full-Scale Mock-Up of Skylight to Evaluate Its Performance Following Standards Criteria&#8221; Arabian Journal for Science and Engineering 47(10): 13407\u201313420. DOI: 10.1007\/s13369-022-06817-2.<\/li>\n<li>[4] M. T. Naqash, A. Formisano, and E. N. Farsangi. \u201cStructural assessment of glass used in fa\u00e7ade industry\u201d. In: Structures. 33. Elsevier. 2021, 4817\u20134827. DOI: 10.1016\/j.istruc.2021.07.059.<\/li>\n<li>[5] A. Standard. ASTM E1300 Standard Practice for Determining Load Resistance of Glass in Buildings. 2012.<\/li>\n<li>[6] U. Knaack and T. Klein, (2013) \u201cJournal of Facade Design and Engineering&#8221; Journal of Facade Design and Engineering 1(1-2): 1\u20131. DOI: 10.3233\/fde-130008.<\/li>\n<li>[7] What\u2019s the Difference Between U-Value and R-Value? URL: https:\/\/glassed.vitroglazings.com\/topics\/thedifference-between-r-value-and-u-value.<\/li>\n<li>[8] Types of Architectural Glass. URL: https:\/\/www.peerlessproducts.com\/media\/blog\/what- glassshould-you-be-choosing-for-all-over-performanceand-aesthetics.<\/li>\n<li>[9] S. W. Duda, (2012) \u201cThe challenge of low energy design in low energy cost states&#8221; ASHRAE Transactions 118(2): 269\u2013276.<\/li>\n<li>[10] M. J. Hewett, V. D. Baxter, D. S. Borges, W. S. Clements, P. A. Domanski, R. A. Evans, J. F. Hogan, R. E. Jarnagin, D. E. Knebel, F. H. Kohloss, et al., (2001) \u201cASHRAE STANDARDS COMMITTEE 1999-2000&#8243;:<\/li>\n<li>[11] A. Standard, (1992) \u201cThermal environmental conditions for human occupancy&#8221; ANSI\/ASHRAE, 55 5:<\/li>\n<li>[12] M. Vaughn, (2014) \u201c2013-2014: ASHRAE research report&#8221; ASHRAE Journal 56(10): 89\u201399.<\/li>\n<li>[13] Saudi &amp; Middle East Green Initiatives. URL: https:\/\/www.greeninitiatives.gov.sa\/?gclid=CjwKCAjwhJukBhBPEiwAniIcNTibvSYgD1qhI-kyZnkCXBPbGqQpDDRiLnuECbSvbBQSBvCy-pSNCNRoCvR8QAvDBwE.<\/li>\n<li>[14] M. Gargallo, B. Cordero, and A. Garcia-Santos, (2021) \u201cMaterial selection and characterization for a novel frameintegrated curtain wall&#8221; Materials 14(8): 1896. DOI: 10.3390\/ma14081896.<\/li>\n<li>[15] B. Cordero, (2015) \u201cThermal performance of novel frameintegrated unitised curtain wall&#8221; Revista de la Construcci\u00f3n. Journal of Construction 14(1): 23\u201331. DOI: 10.4067\/s0718-915&#215;2015000100003.<\/li>\n<li>[16] J. Peng, D. C. Curcija, A. Thanachareonkit, E. S. Lee, H. Goudey, J. Jonsson, and S. E. Selkowitz, (2021) \u201cComparative study on the overall energy performance between photovoltaic and Low-E insulated glass units&#8221; Solar Energy 214: 443\u2013456. DOI: 10.1016\/j.solener.2020.12.006.<\/li>\n<li>[17] A. Aldawoud, (2013) \u201cConventional fixed shading devices in comparison to an electrochromic glazing system in hot, dry climate&#8221; Energy and Buildings 59: 104\u2013110. DOI: 10.1016\/j.enbuild.2012.12.031.<\/li>\n<li>[18] B. P. Jelle, S. E. Kaln\u00e6s, and T. Gao, (2015) \u201cLowemissivity materials for building applications: A state-ofthe-art review and future research perspectives&#8221; Energy and Buildings 96: 329\u2013356. DOI: 10.1016\/j.enbuild.2015.03.024.<\/li>\n<li>[19] E. Kamel and A. M. Memari, (2022) \u201cResidential building envelope energy retrofit methods, simulation tools, and example projects: a review of the literature&#8221; Buildings 12(7): 954. DOI: 10.3390\/buildings12070954.<\/li>\n<li>[20] E. Cuce, C.-H. Young, and S. B. Riffat, (2015) \u201cThermal performance investigation of heat insulation solar glass: A comparative experimental study&#8221; Energy and Buildings 86: 595\u2013600. DOI: 10.1016\/j.enbuild.2014.10.063.<\/li>\n<li>[21] E. Cuce and S. B. Riffat, (2015) \u201cA state-of-the-art review on innovative glazing technologies&#8221; Renewable and sustainable energy reviews 41: 695\u2013714. DOI: 10.1016\/j.rser.2014.08.084.<\/li>\n<li>[22] J. Wang, L. O. Beltr\u00e1n, and J. Kim. \u201cFrom static to kinetic: A review of acclimated kinetic building envelopes\u201d. In: Proceedings of the solar conference. 5. 2012, 4022\u20132029.<\/li>\n<li>[23] S. A. Moghaddam, C. Serra, M. Gameiro da Silva, and N. Sim\u00f5es, (2023) \u201cComprehensive Review and Analysis of Glazing Systems towards Nearly Zero-Energy Buildings: Energy Performance, Thermal Comfort, CostEffectiveness, and Environmental Impact Perspectives&#8221; Energies 16(17): 6283. DOI: 10.3390\/en16176283.<\/li>\n<li>[24] C. T. Do and Y.-C. Chan, (2021) \u201cDaylighting performance analysis of a facade combining daylight-redirecting window film and automated roller shade&#8221; Building and Environment 191: 107596. DOI: 10.1016\/j.buildenv.2021.107596.<\/li>\n<li>[25] C. Garlisi, E. Trepci, X. Li, R. Al Sakkaf, K. Al-Ali, R. P. Nogueira, L. Zheng, E. Azar, and G. Palmisano, (2020) \u201cMultilayer thin film structures for multifunctional glass: Self-cleaning, antireflective and energysaving properties&#8221; Applied energy 264: 114697. DOI: 10.1016\/j.apenergy.2020.114697.<\/li>\n<li>[26] A. Piccolo, M. Prestipino, M. F. Panzera, and R. Baccoli, (2023) \u201cStudy of the Correlation among Luminous Properties of Smart Glazing for Adaptive Energy Saving Buildings&#8221; Buildings 13(2): 337. DOI: 10.3390\/ buildings13020337.<\/li>\n<li>[27] E. Cuce, P. M. Cuce, and S. Riffat, (2016) \u201cNovel glazing technologies to mitigate energy consumption in lowcarbon buildings: a comparative experimental investigation&#8221; International Journal of Energy Research 40(4): 537\u2013549. DOI: 10.1002\/er.3478.<\/li>\n<li>[28] M. T. Naqash, S. Khoso, and E. Noroozinejad Farsangi, (2024) \u201cWind-Induced Structural Response of Skylights: A Eurocode-Based Assessment&#8221; Practice Periodical on Structural Design and Construction 29(1): 04023062. DOI: 10.1061\/PPSCFX.SCENG-1381.<\/li>\n<li>[29] V. Mendon, Z. Taylor, S. Rao, and Y. Xie. 2015 IECC: Energy Savings Analysis. Tech. rep. Pacific Northwest National Lab.(PNNL), Richland, WA (United States), 2015.<\/li>\n<li>[30] P. N. N. Laboratory. Factsheet: The revised Energy Performance of Buildings Directive (EPBD). 2018.<\/li>\n<li>[31] S. Goel and M. I. Rosenberg. ANSI\/ASHRAE\/IES Standard 90.1-2010 Performance Rating Method Reference Manual. Tech. rep. Pacific Northwest National Lab.(PNNL), Richland, WA (United States), 2016.<\/li>\n<li>[32] P. Torcelini, M. Deru, B. Griffith, K. Benne, M. Halverson, D. Winiarski, and D. B. Crawley. DOE commercial building benchmark models. Tech. rep. National Renewable Energy Lab.(NREL), Golden, CO (United States), 2008.<\/li>\n<li>[33] R. American Society of Heating and A.-C. Engineers. ASHRAE STANDARD 55-2004. American Society of Heating, Refrigerating and Air-Conditioning Engineers, 2004.<\/li>\n<li>[34] A. ASHRAE, (2021) \u201cASHRAE Standard 62.1-2022. Ventilation and Acceptable Indoor Air Quality&#8221; American Society of Heating, Refrigerating, and AirConditioning Engineers, Inc.: Atlanta, GA:<\/li>\n<li>[35] O. G. Adekanye, A. Davis, and I. L. Azevedo, (2020) \u201cFederal policy, local policy, and green building certifications in the US&#8221; Energy and Buildings 209: 109700. DOI: 10.1016\/j.enbuild.2019.109700.<\/li>\n<li>[36] C. Ford, (2017) \u201cLeadership in Energy and Environmental Design (LEED)&#8221; The Bloomsbury Encyclopedia of Design; Bloomsbury: London, UK: DOI: 10.5040\/9781472596161-bed-l023.<\/li>\n<li>[37] How LEED works. URL: https:\/\/www.usgbc.org\/leed (visited on 2022).<\/li>\n<li>[38] R. Olu-Ajayi, H. Alaka, I. Sulaimon, F. Sunmola, and S. Ajayi, (2022) \u201cMachine learning for energy performance prediction at the design stage of buildings&#8221; Energy for Sustainable Development 66: 12\u201325. DOI: 10.1016\/j.esd.2021.11.002.<\/li>\n<li>[39] N. Asim, M. Badiei, M. Mohammad, H. Razali, A. Rajabi, L. Chin Haw, and M. Jameelah Ghazali, (2022) \u201cSustainability of heating, ventilation and air-conditioning (HVAC) systems in buildings\u2014An overview&#8221; International journal of environmental research and public health 19(2): 1016. DOI: 10.3390\/ijerph19021016.<\/li>\n<li>[40] F. Ellen, T. Luke, W. Mark, Y. Yunyang, N. Chitra, and L. Jeremy. Enhancing Resilience in Buildings Through Energy Efficiency Pacific Northwest National Laboratory. 2023.<\/li>\n<li>[41] S. Somasundaram, S. R. Thangavelu, and A. Chong, (2020) \u201cImproving building efficiency using low-e coating based retrofit double glazing with solar films&#8221; Applied Thermal Engineering 171: 115064. DOI: 10.1016\/j.applthermaleng.2020.115064.<\/li>\n<li>[42] Daylight | U.S. Green Building Council. URL: https:\/\/www.usgbc.org\/credits\/healthcare\/v4-draft\/eqc0 (visited on 2023).<\/li>\n<li>[43] Buildings &#8211; Energy System &#8211; IEA. URL: https:\/\/www.iea.org\/energy-system\/buildings (visited on 2023).<\/li>\n<li>[44] Smart Buildings Market worth $121.6 billion by 2026 \u2013 Report by MarketsandMarketsTM. URL: https:\/\/www.marketsandmarkets.com\/PressReleases\/smart-building.asp (visited on 2023).<\/li>\n<li>[45] Glazing Properties | Sustainability Workshop. URL: https:\/\/sustainabilityworkshop.venturewell.org\/node\/993.html (visited on 2023).<\/li>\n<li>[46] I. ISO, (2003) \u201c9050: Glass in Building-Determination of Light Transmittance, Solar Direct Transmittance, Total Solar Energy Transmittance, Ultraviolet Transmittance and Related Glazing Factors&#8221; International Organization for Standardization, Geneva:<\/li>\n<li>[47] M. T. Naqash, (2015) \u201cStructural Design Proposal for the Le Boulevard Skylight Doha Qatar&#8221; International Journal of Advanced Structures and Geotechnical Engineering 4(2): 77\u2013103.<\/li>\n<li>[48] U. J. Udi, M. M. Yussof, K. M. Ayagi, C. Bedon, and M. K. Kamarudin, (2023) \u201cEnvironmental degradation of structural glass systems: A review of experimental research and main influencing parameters&#8221; Ain Shams Engineering Journal 14(5): 101970. DOI: 10.1016\/j.asej.2022.101970.<\/li>\n<li>[49] C. Bedon, X. Zhang, F. Santos, D. Honfi, M. Koz\u0142owski, M. Arrigoni, L. Figuli, and D. Lange, (2018) \u201cPerformance of structural glass facades under extreme loads\u2013Design methods, existing research, current issues and trends&#8221; Construction and Building Materials 163: 921\u2013937. DOI: 10.1016\/j.conbuildmat.2017.12.153.<\/li>\n<li>[50] J. Savi\u00b4c, D. \u00d0uri\u00b4c-Mijovi\u00b4c, and V. Bogdanovi\u00b4c, (2013) \u201cArchitectural glass: Types, performance and legislation&#8221; Facta universitatis-series: Architecture and Civil Engineering 11(1): 35\u201345. DOI: 10.2298\/fuace1301035s.<\/li>\n<li>[51] L. Wondraczek, E. Bouchbinder, A. Ehrlicher, J. C. Mauro, R. Sajzew, and M. M. Smedskjaer, (2022) \u201cAdvancing the mechanical performance of glasses: perspectives and challenges&#8221; Advanced Materials 34(14): 2109029. DOI: 10.1002\/adma.202109029.<\/li>\n<li>[52] C. Louter, J. Belis, J. H. Nielsen, M. Overend, and J. Schneider, (2020) \u201cGlass performance&#8221; Glass Structures &amp; Engineering 5(1): 1\u20132. DOI: 10.1007\/s40940-020-00117-7.<\/li>\n<li>[53] M. T. Naqash, (2019) \u201cDesign and fabrication of aluminum cladding and curtain wall of a sports club&#8221; Open Journal of Civil Engineering 9(1): 1\u201317. DOI: 10.4236\/ojce.2019.91001.<\/li>\n<li>[54] M. T. Naqash, A. Formisano, and G. De Matteis, (2016) \u201cDesign and performance testing of a skylight in Qatar&#8221; Key Engineering Materials 710: 262\u2013267. DOI: 10.4028\/www.scientific.net\/KEM.710.262.<\/li>\n<\/ol>\n<\/div>\n\n\n\n<p><\/p>\n","protected":false},"author":3,"template":"wp-custom-template-detail-4-aricles","meta":{"_uag_custom_page_level_css":""},"categories":[9,6,265],"tags":[305],"acf":[],"uagb_featured_image_src":[],"uagb_author_info":{"display_name":"\u6797\u923a\u6db5","author_link":"\/jase\/?author=3"},"uagb_comment_info":0,"uagb_excerpt":"&nbsp;Copyright&nbsp;The Author(s). This is an open access article distributed under the terms of the&nbsp;Creative Commons Attribution&nbsp;License (CC BY 4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are cited. Download Citation:\u00a0 BibTeX | http:\/\/dx.doi.org\/10.6180\/jase.202502_28(2).0011\u00a0\u00a0 Download PDF As the climate of the globe changes, buildings will need to&hellip;","_links":{"self":[{"href":"\/jase\/index.php?rest_route=\/wp\/v2\/tkuisotope\/2236"}],"collection":[{"href":"\/jase\/index.php?rest_route=\/wp\/v2\/tkuisotope"}],"about":[{"href":"\/jase\/index.php?rest_route=\/wp\/v2\/types\/tkuisotope"}],"author":[{"embeddable":true,"href":"\/jase\/index.php?rest_route=\/wp\/v2\/users\/3"}],"wp:attachment":[{"href":"\/jase\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=2236"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"\/jase\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=2236"},{"taxonomy":"post_tag","embeddable":true,"href":"\/jase\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=2236"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}